MSTS=others
Main Clock Oscillator Wait Control Register
MSTS | Main clock oscillator wait time setting 0 (0000): Wait time= 3 cycles (11.4us : calculated at LOCO=262.144KHz (3.81us TYP.)) 0 (others): Setting prohibited 1 (0001): Wait time= 35 cycles (133.5us : calculated at LOCO=262.144KHz (3.81us TYP.)) 2 (0010): Wait time= 67 cycles (255.6us: calculated at LOCO=262.144KHz (3.81us TYP.)) 3 (0011): Wait time= 131 cycles (499.7us: calculated at LOCO=262.144KHz (3.81us TYP.)) 4 (0100): Wait time= 259 cycles (988.0us: calculated at LOCO=262.144KHz (3.81us TYP.)) 5 (0101): Wait time= 547 cycles (2086.6us: calculated at LOCO=262.144KHz (3.81us TYP.)) 6 (0110): Wait time= 1059 cycles (4039.8us: calculated at LOCO=262.144KHz (3.81us TYP.)) 7 (0111): Wait time= 2147 cycles (8190.2us: calculated at LOCO=262.144KHz (3.81us TYP.)) 8 (1000): Wait time= 4291 cycles (16368.9us: calculated at LOCO=262.144KHz (3.81us TYP.)) 9 (1001): Wait time= 8163 cycles (31139.4us: calculated at LOCO=262.144KHz (3.81us TYP.)) |
Reserved | These bits are read as 0000. The write value should be 0000. |